XAI 기반 발전설비 고장 기록 데이터 품질 향상 시스템 개발
김유림, 박정인, 박동현, 강성우
인하대학교 산업경영공학과
Development of System for Enhancing the Quality of Power Generation Facilities Failure History Data Based on Explainable AI (XAI)
Yu Rim Kim, Jeong In Park, Dong Hyun Park, Sung Woo Kang
Department of Industrial Engineering, Inha University
Correspondence  Sung Woo Kang ,Email: kangsungwoo@inha.ac.kr
Received: June 12, 2024; Revised: July 10, 2024   Accepted: July 23, 2024.  Published online: September 30, 2024.
ABSTRACT
Purpose:
The deterioration in the quality of failure history data due to differences in interpretation of failures among workers at power plants and the lack of consistency in the way failures are recorded negatively impacts the efficient operation of power plants. The purpose of this study is to propose a system that classifies power generation facilities failures consistently based on the failure history text data created by the workers.
Methods:
This study utilizes data collected from three coal unloaders operated by Korea Midland Power Co., LTD, from 2012 to 2023. It classifies failures based on the results of Soft Voting, which incorporates the prediction probabilities derived from applying the predict_proba technique to four machine learning models: Random Forest, Logistic Regression, XGBoost, and SVM, along with scores obtained by constructing word dictionaries for each type of failure using LIME, one of the XAI (Explainable Artificial Intelligence) methods. Through this, failure classification system is proposed to improve the quality of power generation facilities failure history data.
Results:
The results of this study are as follows. When the power generation facilities failure classification system was applied to the failure history data of Continuous Ship Unloader, XGBoost showed the best performance with a Macro_F1 Score of 93%. When the system proposed in this study was applied, there was an increase of up to 0.17 in the Macro_F1 Score for Logistic Regression compared to when the model was applied alone. All four models used in this study, when the system was applied, showed equal or higher values in Accuracy and Macro_F1 Score than the single model alone.
Conclusion:
This study propose a failure classification system for power generation facilities to improve the quality of failure history data. This will contribute to cost reduction and stability of power generation facilities, as well as further improvement of power plant operation efficiency and stability.
Key Words: Power Generation Facilities, Quality Improvement, Natural Language Processing, XAI, LIME
Editorial Office
1806, 310, Gangnam-daero, Gangnam-gu, Seoul, 06253, Korea
TEL: +82-2-563-0357   FAX: +82-2-563-0358   E-mail: ksqmeditor@ksqm.org
About |  Browse Articles |  Current Issue |  For Authors and Reviewers
Copyright © The Korean Society for Quality Management.                 Developed in M2PI
Close layer
prev next